Chronic Fatigue Syndrome Research Today is a free monthly online journal that collates and summarizes the latest research about Chronic Fatigue Syndrome, including details on myalgic encephalomyelitis (me), diagnosis, gradual and sudden onset. | ||||||||
|
Two human hydroxyapatite-coated dental implants retrieved after a 14-year loading period: a histologic and histomorphometric case report.Iezzi G, Scarano A, Petrone G, Piattelli A Dental School, University of Chieti-Pescara, Chieti, Italy. BACKGROUND: Controversy over the long-term clinical effectiveness of hydroxyapatite (HA)-coated dental implants still persists, despite numerous clinical studies documenting high survival rates. Concerns about the degradation of the coating over the years have been raised; it has been speculated that resorption of the HA could produce a space between the implant and the bone with a resultant mechanical instability. METHODS: Two HA-coated implants were retrieved due to a fracture of the abutment screws after a loading period of 14 years and were treated to obtain thin ground sections for histologic evaluation. RESULTS: At low-power magnification, it was possible to observe that the HA coating was in contact with mature bone. No gaps or connective fibrous tissue was found at the implant-bone interface. No epithelial downgrowth was present. No acute or chronic inflammatory cell infiltrate was present at the implant-bone interface. No foreign body reaction was present in the peri-implant tissues. Some osteocytes were in direct contact with the coating. For implant 1, the percentage of bone-titanium contact was 25% +/- 2.1%, and the percentage of bone-HA contact was 35% +/- 1.4%. The total bone-implant contact was approximately 60%. The HA coating appeared to be resorbed in 46% +/- 3.2% of the implant perimeter, especially in the coronal portions of the implant. For implant 2, the mean percentage of bone-HA contact was 13% +/- 1.8%, and the mean percentage of bone-titanium contact was 15% +/- 2.3%. The total bone-implant contact was approximately 28%. The HA coating appeared to be resorbed for a mean of 68% +/- 4.1% of the implant perimeter, especially in the coronal portion of the implant. CONCLUSIONS: No acute or chronic inflammatory cell infiltrate was present in the peri-implant tissues. No signs of coating infection, fatigue, or failure were observed in two specimens. The HA coating may not be susceptible to degradation or dissolution under long-term function. Published 1 May 2007 in J Periodontol, 78(5): 940-7.
© 2005-2008 Chronic Fatigue Syndrome Research Today. All Rights Reserved. |
| ||||||